Liste thèses soutenues

webTV

Lecture

Carlos Adrian Correa Florez, MINES ParisTech PhD, PERSEE center

Lecture

Smart4RES

Lecture

CoRDÉES : gouvernance énergétique de quartier

Lecture

Prédiction solaire pour des suiveurs photovoltaïques

Lecture

The REstable project

+ TOUS

Maria NIZNIK - Soutenance de thèse Mines Paris -PSL

Maria NIZNIK

Amélioration et intégration d'une méthode d'affichage des performances en temps réel d'une pompe à chaleur

Titre anglais : Improvement and integration of the in-situ heat pump performance assessment method
Date de soutenance : 10/07/17
Directeur de thèse : Dominique MARCHIO

Mots clés en français : Pompe à chaleur air/air,performances saisonnières,compresseur,modélisation,garantie de performance,détection de défauts,
Mots clés en anglais : Air-to-air heat pump,seasonal performances,compressor,modeling,performance guarantee,fault detection,

Résumé de la thèse en français
Actuellement, la plupart des fabricants de pompes à chaleur (PAC) fournissent les valeurs de coefficients de performances (COP) obtenus en laboratoire en conditions contrôlées et standardisées. Une méthode prometteuse, appelée méthode de mesure des performances dans la suite, d'évaluation des performances de PAC in situ, basée sur le bilan énergétique du compresseur, a été présentée par Tran et al. (2013). Cette méthode détermine le débit de fluide frigorigène et est compatible avec différents types de PAC, notamment air-air, et des cycles frigorifiques plus complexes. Tran et al. (2013) ont déterminé que l'incertitude sur l'évaluation de pertes thermiques du compresseur contribue à hauteur de 40% sur l'erreur d'estimation de la puissance thermique. L'objectif de cette thèse est d'établir une méthode simplifiée quant à l'instrumentation pour mesurer les pertes thermiques in situ. Pour cela, deux modèles numériques détaillés sont développés afin d'examiner la distribution de température sur l'enveloppe de deux types de compresseurs, scroll et rotary. Les mesures expérimentales fournies par un fabricant de compresseurs, Mitsubishi Heavy Industries (MHI), sont utilisées pour calibrer et valider les modèles numériques. Ces derniers permettent de définir deux protocoles de mesures différents pour les deux compresseurs. Ensuite, le protocole établi pour le compresseur rotary est intégré dans la méthode de mesures des performances. Les puissances thermiques calculées sont comparées avec des valeurs de référence, obtenues à partir d'un prototype en banc d'essai à EDF Lab Les Renardières.

Résumé de la thèse en anglais
Currently, most heat pump(HP) manufacturers provide coefficient of performance (COP) values obtained in laboratories under standardized controlled operating conditions. These COP values are not necessarily representative of those obtained on-field. A promising method, referred to as the performance assessment method, that measures heat pump performances in-situ based on compressor energy balance, was presented by Tran et al. (2013). The method determines refrigerant mass flow rate and has the capability of measuring performances of various HP types, such as air-to-air, as well as more complex refrigeration cycles. The method abstains from intrusive measurements, and is, therefore, perfectly suitable for in-situ measurements. As shown in the work of Tran et al. (2013), compressor heat losses account for 40% in the final uncertainty of performance values obtained with the performance assessment method. The objective of this thesis is to establish a rather simplified measurement method, in terms of instrumentation, that is used to determine compressor heat losses in-situ. For this purpose two detailed numerical models for assessing the temperature fields of the scroll and rotary compressor shells were developed. Experimental measurements obtained with the help of compressor manufacturer, Mitsubishi Heavy Industries (MHI), are used to validate and calibrate the numerical models. The developed numerical models allow to define two different measurement protocols for both compressors. Established compressor heat loss protocol for rotary compressor is then integrated in the performance assessment method and the obtained heating capacities are compared with reference measurements in an experimental test bench in EDF Lab Les Renardières.

Retour à la liste des thèses soutenues

- Mines Paris - PSL
Partager

actualité

240 ans de recherche et de formation

Ecole 240 ans de recherche et de formation Vidéo : 240ans de recherche…
> En savoir +

Mines Paris plébiscitée par ses étudiantes

Formation Mines Paris plébiscitée par ses étudiantes Mines Paris - PSL, une école qui répond…
> En savoir +

Femmes de science

Formation Femmes de science Chercheuses confirmées, doctorantes, élèves ou alumni,…
> En savoir +

Quelle école d’ingénieurs a le meilleur réseau LinkedIn ?

Formation Quelle école d’ingénieurs a le…  Mines Paris - PSL au Top 5 du classement LinkedIn 2023…
> En savoir +

Virginie Ren remporte un Trophée Veolia de la transformation écologique

Formation Virginie Ren remporte un Trophée Veolia de la… Virginie Ren, ingénieure Mines Paris - PSL, en…
> En savoir +

Agathe Gilain, Prix de droit, économie et sociologie du transport aérien et spatial 2O22

Formation Agathe Gilain, Prix de droit, économie et… L’Académie de l’Air et de l’Espace…
> En savoir +

+ Toutes les actualités

Plan du site
Mentions légales efil.fr © 2014 Mines Paris - PSL